Customization: | Available |
---|---|
Type: | Li-ion Battery |
Cathode Material: | LCO |
Still deciding? Get samples of US$ 1.55/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item | Rating | Note | |
3.1 Capacity |
Typical | 1050mAh |
Discharge:0.2CmA cut off Voltage:3V for cell |
Mininum | 1000mAh | ||
3.2 Nominal Voltage | Average 3.7V | ||
3.3 AC Impedance Resistance | ≤120mΩ | ||
3.4 Discharge Cut-off Voltage | 3.0V | ||
3.5 Charge Current | 220mA | Standard Charge | |
3.6 Charge Voltage | 4.2V | ||
3.7 Storage Humidity | <75%RH | ||
3.8 Max. Charge Current | 1050mA | ||
3.9 Charge time | Approx 2.5h | ||
3.10. Max discharge current | 1050mA | ||
3.11 Weight | Approx 16.5g | Charge: 1.0CmA | |
3.12 Operating Temperature |
Charge | 0~+45ºC | |
Discharge | -20~50ºC | ||
3.13 Storage Temperature |
less than1 month | -20~45ºC | Recommended storage temperature: 20ºC,at the shipment state |
less than 3 months | -20~35ºC |
Product picture:
Performance
1 Standard Test Conditions
Test should be conducted with new batteries within one month after shipment from our factory and the cells shall not be cycled more than five times before the test. Unless otherwise defined, test and measurement shall be done under temperature of 25±2ºC and relative humidity of 45~85%. The test results are not affected evidently by such conditions of temperature 15~30ºC or humidity 25~85%RH.5.2 Measuring Instrument or Apparatus.
2 Measuring Instrument or Apparatus
2.1 Dimension Measuring Instrument
The dimension measurement shall be implemented by instruments with equal or more precision scale
of 0.01mm.